Analisa Hasil Pengelasan Antara Trafo Las Kumparan Lilitan Pabrikan Dengan Konvensional

Authors

  • Usman Program Studi Tekniki Listrik Bandara, Politeknik Penerbangan Medan, Jl. Penerbangan No. 85 Jamin Ginting KM 8,5 Padang Bulan, Medan, Sumatera Utara, Indonesia
  • Catra Indra Cahyadi Program Studi Tekniki Listrik Bandara, Politeknik Penerbangan Medan, Jl. Penerbangan No. 85 Jamin Ginting KM 8,5 Padang Bulan, Medan, Sumatera Utara, Indonesia
  • Paino Program Studi Tekniki Listrik Bandara, Politeknik Penerbangan Medan, Jl. Penerbangan No. 85 Jamin Ginting KM 8,5 Padang Bulan, Medan, Sumatera Utara, Indonesia
  • Eriansyah S Hasibuan Program Studi Tekniki Listrik Bandara, Politeknik Penerbangan Medan, Jl. Penerbangan No. 85 Jamin Ginting KM 8,5 Padang Bulan, Medan, Sumatera Utara, Indonesia

DOI:

https://doi.org/10.51544/jurnalmi.v9i1.5027

Keywords:

Transformator Kumparan Lilitan Pabrikan dan Konvensional,, hasil pengelasan, Uji Bending

Abstract

The electric welding system requires a welding transformer that is usually classified as direct current (DC) or alternating current (AC). In electric welding, a separate transformer is provided as a source for regulating the required current during the welding process. The operation of the transformer during welding is closely related to the needs of the current, the diameter of the welding wire, and the thickness of the material being welded. The difference between a conventional coil winding transformer and a manufacturer's coil winding transformer lies in the welding results and the specimens obtained from testing a type of material, which is steel plate ST37 with a thickness of 8mm and a width of 40mm, using electrodes E-6013 with diameters of 2.6mm and 3.2mm. The welding joint method used is a single V groove butt joint. The welding tests of both transformers prove that the penetration, width, and height of the weld bead with the Manufacturer's coil winding transformer are quite good compared to the Conventional coil winding transformer. Based on the welding test results of both transformers, the Manufacturer's coil winding transformer using electrode type E-6013 achieved the highest bending test strength with a Crack load value of 33.701 kN, while the Conventional coil winding transformer had a value of 27.335 kN, both using the same current of 120 Amperes.".

Downloads

Download data is not yet available.

References

Jasman, Huda N. Pengaruh Kuat Arus terhadap Uji Tarik Baja Karbon Rendah Menggunakan Metal Inert Gas (MIG). Ranah Res. 2019;2(1):219–29.

Nata OD, Hidayat M, Rohman SA. Analisis Kekuatan Uji Bending Pengelasan Shielded Metal Arc Welding (Smaw) Material Ss400 Menggunakan Kawat Las E6013 Berbagai Variasi Arus Listrik. Hexag J Tek dan Sains. 2021;2(1):12–5.

Maulid R, Tuparjono, Dharta Y. Analisis Uji Bending Pada Pengelasan Baja St37Menggunakan Las Smaw (Shield Metal Arc Welding)Dengan Posisi Pengelasan 1G. J Pros Semin Nas Inov Teknol Terap. 2022;2(1):342–8.

Sedjati, Wulandari. Analisa Pengaruh Jumlah Lilitan Dan Diameter Tembaga Pada Trafo Terhadap Daya Output Mesin Spot Welder And Soldering Iron Semi Portable. J Rekayasa Mesin. 2022;07(1):24–33.

Wilian E. Surface Roughness Baja St 37 Pada Proses Bubut Menggunakan Mata Pahat Karbida. Skripsi. 2018;1–58.

Fandi. Teknik Las GTAW Teknik Las GTAW. In: Kementrian Pendidikan dan Kebudayaan. 2013. p. 91.

Downloads

Published

2024-06-30

How to Cite

Usman, Cahyadi, C. I., Paino, & Hasibuan, E. S. (2024). Analisa Hasil Pengelasan Antara Trafo Las Kumparan Lilitan Pabrikan Dengan Konvensional. JURNAL MAHAJANA INFORMASI, 9(1), 19–24. https://doi.org/10.51544/jurnalmi.v9i1.5027